Current Issue : July - September Volume : 2021 Issue Number : 3 Articles : 5 Articles
Background: Intraoperative coronary angiography can tremendously reduce early coronary bypass graft failures. Fluorescent cardiac imaging provides an advanced method for intraoperative observation and real-time quantitation of blood flow with high resolution. Methods: We devised a system comprised of an LED light source, special filters, lenses and a detector for preclinical coronary artery angiography. The optical setup was implemented by using two achromatic doublet lenses, two positive meniscus lenses, a band-pass filter, a pinhole and a CCD sensor. The setup was optimized by Zemax software. Optical design was further challenged to obtain more parallel light beams, less diffusion and higher resolutions to levels as small as arterioles. Ex vivo rat hearts were prepared and coronary arteries were retrogradely perfused by indocyanine green (ICG). Video angiography was employed to assess blood flow and plot time-dependent fluorescence intensity curve (TIC). Quantitation of blood flow was performed by calculating either the gradient of TIC or area under curve. The correlation between blood flow and each calculated parameters was assessed and used to evaluate the quality of flow. Results: High-resolution images of flow in coronary arteries were obtained as precise as 62 μm vessel diameter, by our custom-made ICG angiography system. The gradient of TIC was 3.4–6.3 s−1, while the area under curve indicated 712–1282 s values which ultimately gained correlation coefficients of 0.9938 and 0.9951 with relative blood flow, respectively. Conclusion: The present ICG angiography system may facilitate evaluation of blood flow in animal studies of myocardial infarction and coronary artery grafts intraoperatively....
Introduction: The appendix is identified as blind ending tubular structure arising from caecum and has variable intraluminal contents and position. Acute appendicitis is one of the common indications for emergency imaging studies. Aim: To describe the importance of appendix hyperattenuation and densities. Material and Methods: Contrast enhanced computed tomography images of abdomen from 120 patients with surgically/pathological proven acute appendicitis, were examined retrospectively. The images were reviewed in axial, coronal and sagittal reformations for assessing the intraluminal contents (hyperdensity and appendicolith), maximum transverse diameter and single wall thickness of appendix, periappendiceal fat stranding and other parameters related to acute appendicitis. In addition, reviewing 100 pre- and post-contrast CT scans of other abdominal conditions as a control group for documenting hyperdense appendix, appendicolith and other signs.................
Background: Non-invasive imaging is of interest for tracking the progression of atherosclerosis in the carotid bifurcation, and segmenting this region into its constituent branch arteries is necessary for analyses. The purpose of this study was to validate and demonstrate a method for segmenting the carotid bifurcation into the common, internal, and external carotid arteries (CCA, ICA, ECA) in contrast-enhanced MR angiography (CE-MRA) data. Methods: A segmentation pipeline utilizing a convolutional neural network (DeepMedic) was tailored and trained for multi-class segmentation of the carotid arteries in CE-MRA data from the Swedish CardioPulmonsary bioImage Study (SCAPIS). Segmentation quality was quantitatively assessed using the Dice similarity coefficient (DSC), Matthews Correlation Coefficient (MCC), F2, F0.5, and True Positive Ratio (TPR). Segmentations were also assessed qualitatively, by three observers using visual inspection. Finally, geometric descriptions of the carotid bifurcations were generated for each subject to demonstrate the utility of the proposed segmentation method...............
Ionizing radiation is widely used in medical practice for both diagnostic and therapeutic purposes. However, they are not devoid of adverse health effects on exposed operators. Therefore, we propose to assess the radiological risk of the interventional radiology team of the International Polyclinic of Indénié of Abidjan during the procedures of Embolization of uterine fibromyomas. The effective and equivalent doses to the extremities and crystals were estimated by TLD dosimeters positioned at different body areas selected on the basis of a radiological analysis of the exposure of personnel during five procedures. The analysis of fluoroscopic and record times showed variability in or an average fluoroscopy time of 32.37 min with extremes............
Introduction: Owing to the advanced development of MRI science, it causes obvious great changes of many diseases that affect the female genital system and affect their fertility. Hemorrhagic gynecological diseases especially endometriosis affect young females and cause cyclic pain, in addition to infertility. So early detection is essential for proper treatment. Susceptibility-weighted (SWI) as one of the most recent newly created MRI sequences is highly sensitive to detect products of hemorrhage within different gynecologic disorders with 94.7% sensitivity being more meticulous than conventional MRI sequences as T1 and T2. Aim of the Work: A comparison between T1 and T2 as conventional MRI sequences with susceptibility-weighted images (SWI) in many gynecologic disorders by the detection of the presence of internal products of hemorrhage at any stage..................
Loading....